| PM-A-2001 |
Zone 2 Diesel Powerpack is Fitted with Air Starter System, has a Hydraulic Tank of 205 litres (45 gallons), a Fuel Tank of 60 litres (14 gallons) with a System pressure set of 2,200 psi.
|
 |
| PM-A-2005 |
Zone 2 Diesel Powerpack has a Hydraulic Tank of 220 litres (49 gallons), and a Fuel Tank of 70 litres (15.5 gallons) with a System pressure set of 3,000 psi, the system has 2 pumps, Pump 1 (Wireline) is 35 GPM @ 2,100 rpm and Pump 2 (Mast) is 11 GPM @ 2,100 rpm, the powerpack is fitted with inertia Starter System |
 |
| PM-A-2003 |
Lightweight 'heli-portable' Zone 2 Powerpack with a Hydraulic Tank of 220 litres (49 gallons) and a Fuel Tank fo 67 litres (15 gallons) with a System pressure set of 3,000 psi, the system has 2 pumps, Pump 1 has 35 GPM @ 2,100 rpm and Pump 2 has 11 GPM @ 2,100 rpm, the system is fitted with inertia Starter System |
 |
| PM-A-2002 |
Lightweight 'heli-portable' Zone 2 Powerpack with a Hydraulic Tank of 220 litres (49 gallons), a Fuel Tank of 67 litres (15 gallons) with a System pressure set of 3,000 psi; the system has a Pump which is 35 GPM @ 2,100 rpm; it is fitted with inertia Starter System. |
 |
| PM-A-2004 |
Lightweight 'heli-portable' Zone 2 Powerpack with a Hydraulic Tank of 220 litres (49 gallons) and a Fuel Tank of 67 litres (15 gallons), the System pressure set is set to 3,000 psi for wireline units and 2,500 psi for Triplex pumps. The pump is set to 35 GPM @ 2,100 rpm, and is fitted with inertia Starter System. |
 |
| PM-A-2006 |
Zone 2 Diesel Powerpack has 3 pumps;
Pump 1 – Wireline System:
Open loop van pump 35 GPM @ 2100 RPM
System Pressure: 3000 PSI
Pump 2 – Mast System:
Load sensing pump 11 GPM @ 2100 RPM
System pressure: 2000 PSI
Pump 3 – Engine start and BOP supply system , gear pump
System Pressure: 2000 PSI |
 |
| PM-A-2007 |
Zone 2 Diesel Powerpack has 3 pumps:
Pump 1 – Wireline System: Open loop van pump 35 GPM @ 2100 RPM
SYSTEM PRESSURE 3000 PSI
Pump 2 – Mast System: Load sensing pump 11 GPM @ 2100 RPM
SYSTEM PRESSURE 2000 PSI
Pump 3 – Engine start and BOP supply system , gear pump
SYSTEM PRESSURE 2000 PSI |
 |
| PM-A-2008 |
Zone 2 Diesel Powerpack has 2 pumps:
Pump 1 –
Wireline System: Open loop van pump 35 GPM @ 2100 RPM
SYSTEM PRESSURE 3000 PSI
Pump 2 –
Engine start, gear pump
SYSTEM PRESSURE 2000 PSI |
 |
| PM-A-2009 |
Zone 2 Diesel Powerpack has 1 pump;
Pump 1 – Wireline System:
Open loop van pump 35 GPM @ 2100 RPM
System Pressure: 3000 PSI |
 |
| PM-A-2010 |
Zone 2 Diesel Powerpack has 1 pump:
Pump 1 – Wireline System: Open loop van pump 35 GPM @ 2100 RPM